Working Hours: 10AM - 6 PM (or)
Fill Service Request Form
Cvent-1500T advance intensive care ventilator integrated with state of art SWISS MADE CMOSens flow sensor technology for fastest sensing & accurate flow delivery to Neonatal - Adult (Tidal volume from 2ml to 2000ml)
· Easy to use interface, 15” Color TFT display with Touch Screen Key pad/Touch Screen Lock facility for protection against accidental/un intentional changes
· Simultaneously display of Three Waveforms & Three Loops
· Multi level mechanism for patient safety with intelligent high alert alarming system, hence increase safety of operation Three Level color coded audio-visual alarms
· Maintenance - free, auto self testing and no need routine calibration of flow sensor
· Fixed reusable flow sensor hence no daily recurring cost
· Lowest in class bias flow 2.0 L/min, Low o2 consumption
· Automatic Tube & leakage compensation technology
· Advance Pre Test System before use , assured the professions to safely use of machine on patients
· Medical air compressor (Model AF-12) option ensures a constant, compressed air supply in case main central line fail. Unique anti vibration design assures low noise & quiet operation with sound level
· Air Compressor driven technology which makes, more accurate in spontaneous delivery
· Humidifier option ensure a high level of gas humidification to patient
· Anti condensation heated exhalation system with auto sterilization can (Make ICU infection free)
· Auto-Cleavable at 134 degree can use safely and prevent cross infection
· Low maintenance cost, Easily removable, trouble free Active Exhalation Valve technology
· Up gradable to Capnography (EtCO2) &Pulse Oximetry (Spo2)*
· SmartVent (Adaptive Ventilation Mode)
- Intelligent mode of ventilation-Easy to Use & lung protective
- Ensure the guaranteed minute ventilation breath by breath at lowest inspiration pressure and helps patient for spontaneously activity from start of ventilation
- Automatically set Parameters according to Body Weight
- Auto Synchronous the flow on patient demand, Improve Patient Outcome, and avoid ventilator fighting on Spontaneous
- Results shorter ventilation times
· PRVC (Pressure Regulated Volume Control)
- Advanced Dual Modes Make Cvent More Comfortable to patient Wean Case to Case
- Deliver Preset Tidal Volume at Same Rate with the Lowest Possible Pressure
· DuoVent/ APRV Mode (Resistance Free Ventilation)
- Provide lung protective ventilation, Use an “open lung” approach including alveolar recruitment, improved oxygenation. in ARDS patients.
- Pressure support setting in both lunge for spontaneous breathing to patients.
· NIV S/T (Non-Invasive with Synchrony Feature)
- More Unique Benefits , High Performance Non Invasive Ventilation. Also Set Trigger, Rate with Additional Parameters
· nCPAP/nBPAP
- Most effective therapy , used worldwide , Cvent also recommend to use NIV option in newborns.
· VG Option ( Volume Guarantee)*
- New Approaches in volume control ventilation for neonatal have Potential advantages of less risk for barotraumas becouse the tidal volume delivered is limited Reduced peak pressure especially when the baby makes a significant contribution from spontaneous effort
Patient Type |
Adult |
Pediatric |
Neonatal (Optional) |
Modes |
VCV, SIMV-VC, PCV,SIMV-PC, PSV, CPAP+Apnea Backup, APRV, DuoVent, PRVC, SIMV-PRVC,VS* SmartVent (Optional) Non-Invasive: BiPAP,BiPAP-S BiPAP-ST, HFNC/O2 Therapy |
VCV, SIMV-VC, PCV, SIMV-PC, PSV, CPAP+Apnea Backup, APRV, DuoVent, PRVC, SIMV-PRVC,VS* SmartVent (Optional) Non-Invasive: BiPAP,BiPAP-S BiPAP-ST, HFNC/O2 Therapy |
IPPV, SIPPV, SIMV, PSV, CPAP, VCV Non-Invasive: nCPAP, nBPAP O2 Therapy |
Tidal Volume |
150-2000 ml |
10-500 ml |
2-100 ml |
Frequency |
1-100 bpm |
4-150 bpm |
4-200 bpm |
Apnea Back Up Frequency |
4-50 bpm |
4-80 bpm |
2-100 bpm |
Apnea Time |
3-45 Seconds |
3-45 Seconds |
3-45 Seconds |
O2 Therapy Flow |
1-60 L/min |
1-50 L/min |
1-40 L/min |
Inspiration time |
0.1- 12 S (increment:0.1S) |
0.1- 12 S (increment:0.1S) |
0.1- 3 S (increment:0.1S) |
T_Pause/T_Rise |
0-50% /Auto |
||
FiO2 |
21%-100% , 100% O2 (0-5 minutes) |
||
Trigger |
Flow Trigger :0 to 20 L/min, Pressure Trigger : – 20 to 0 cm H2O,ETS: % 5 to 80% |
||
Flow range/Pattern |
0-120 L/min, Square, Decelerating |
||
Pressure Control |
5-120 cmH2O |
||
Pressure Support |
0-120 cmH2O |
||
Electronic PEEP |
0-50 cm H2O (increment:1 cm H2O) |
||
I:E Ratio |
1:9.9 – 9.9:1 |
||
Nebulizer |
0-30 minutes (Particle Size Optional |
||
Waveforms & Loops |
Waveforms : P-T, F-T, V-T , Etco2* , Spo2* & Loops : P-V, F-V, P-F |
||
Recall / Review |
1500 alarm events , 72 Hours Numerical & Graphical Trends, Saved loops with comparison (optional)* , 8 - Hours Breath to Breath Waveform Review (Optional)* |
||
Monitoring Parameters |
Ppeak, Pmean, Pplat, PEEP, VTi, VTe, MVe, MV_cont., MV_spont, F_Peak_ insp, F_ Peak_ Exp, Leak%, Freq, F_cont., F_spont, % F spont, I:E, Ti,Te,Ti/T total, FiO2, (Spo2,Etco2-optional)* Cstat, Cdyn, Rins, Rexp, RSBI, WOB, Auto PEEP, MIP, P0.1, TC, C/C20 |
||
Alarm |
Three Level Audio-visual color coded alarms includes VTe high/low, MV high/low, Tidal volume not reached, High leak Peak Pressure high/low, Pressure limitation, O2 supply pressure high/low/fail, Air supply pressure high/low/fail, Apnea, Apnea Backup, Freq high/low, FiO2 high/low, Circle Block, Circuit disconnection, Expiatory block Power: AC Power Fail, Low Battery, Battery too Low |
||
GENERAL |
|
||
Dimensions/Weight |
530x480x390 mm (LxWxH) / 18Kg |
||
Communication Interface |
VGA, USB, RS232* (optional), CO2,SpO2. |
||
Display |
15 inch color TFT with Capacitive Touch Screen (Ratable) |
||
Air/Oxygen Gas supply |
2.4 to 6.0 bar central supply or integrated Air Compressor (AF-12)-Optional-Humidier |
||
Power Supply |
100-265V AC, 50/60Hz, 1A, 100 VA ,Battery 9.6V,9Ah Lithium Ion Phosphate ,(LiFePO4) Backup > 180min. |
||
SAFETY STANDARD |
|
||
Basic Construction |
In accordance with IEC 60601-1, IEC 60601-1-2 & EMC 60601-2 |
||
Unit Type |
Class 1, Type B, Ip21 |
||
Working Environment |
Temperature : 10 To 40°c , Relative Humidity : 10 To 90% Non Condensing |
Regarding any queries.